87.      Garden Suites

Garden Suites shall be developed in accordance with the following regulations:

Charter Bylaw 19503

February 9, 2021

  1. The minimum Site Width for a Garden Suite shall be the same as the minimum Site Width prescribed for the principal Dwelling in the underlying Zone.

  2. The maximum Height shall be as follows:

  1. 6.5 m where the Garden Suite has a roof slope of 4/12 (18.4°) or greater.

  2. 6.2 m where the Garden Suite has a roof slope of less than 4/12 (18.4°).

  3. notwithstanding (a) and (b) above, in the case of the TSDR, TSLR, RF5g, GLD and the GLG zones, the maximum Height shall be 7.5 m.

  4. notwithstanding (a), (b) and (c) above, where there is no Lane Abutting the Site, the maximum Height shall be 4.3 m.

  5. notwithstanding Section 52.1(b), Height shall be determined by measuring from the horizontal plane through Grade to the highest point of the parapet where a Garden Suite has a flat roof.

Charter Bylaw 18662

February 25, 2019

  1. Floor Area shall be provided in accordance with the following:

  1. for the purposes of this regulation, Floor Area shall exclude Basement areas within the Garden Suite, up to 6 m2 of the area covered by elevators and any associated landing area on each storey, and up to 6 m2 of the area covered by stairways;

  2. the maximum total Floor Area for a Garden Suite shall be 130 m2;

  3.  in the RF1, RF2, RF3, RF4, RF5, RF6, RA7, RA8, and RA9 Zones, the maximum Second Storey Floor Area shall be 50 m2, except where the Garden Suite complies with the regulations of Section 93 the maximum Second Storey Floor Area shall be 60 m2; and

  4. in all other Zones, the maximum Second Storey Floor Area shall be 60 m2.

  1. Notwithstanding the maximum Site Coverage prescribed for Accessory Buildings in the underlying Zone:

  1.  in the RF1, RF2, RF3, RF4, RF5, RF6, RA7, RA8, and RA9 Zones:

  1. the maximum Site Coverage of a Garden Suite shall be in accordance with the following:

  1. the total maximum Site Coverage of the Garden Suite and other Accessory buildings shall not exceed 18%;

  2. the total maximum Site Coverage of other Accessory buildings and any Parking Area within the Garden Suite shall not exceed 12%; and

  3. the total maximum Site Coverage including Accessory buildings and the principal Dwelling shall not exceed the total maximum Site Coverage as prescribed by the regulations of the underlying Zone by more than 2% of Site Area.

  1. in all other Zones:

  1. the maximum Site Coverage of a Garden Suite shall be increased by 2% of Site Area provided that:

Charter Bylaw 18387

May 7, 2018

  1. the total maximum Site Coverage of other Accessory buildings and any Parking Area within the Garden Suite shall not exceed the maximum Accessory building Site Coverage as prescribed by the regulations of the underlying Zone; and

  2. the total maximum Site Coverage including Accessory buildings and the principal Dwelling shall not exceed the total maximum Site Coverage as prescribed by the regulations of the underlying Zone by more than 2% of Site Area.

  1. A Garden Suite shall be located not less than 18.0 m from the Front Lot Line.

  2. Where the vehicle doors face a Lane Abutting the Rear Lot Line, the minimum Rear Setback shall be 1.2 m.

  3. Where the vehicle doors do not face a Lane Abutting the Rear Lot Line, the minimum Rear Setback shall be 0.6 m.

  4. The minimum Side Setback shall be the same as that prescribed for Single Detached Housing within the underlying Zone or applicable Overlay.

  5. The minimum distance between a Garden Suite and the principal Dwelling on the same Site, shall be 4 m.

  6. Where a Garden Suite contains a Parking Area, the Garden Suite shall have an entrance separate from the vehicle entrance to the Parking Area, either from a common indoor landing or directly from the exterior of the structure.

  7. Where a Garden Suite is two Storeys, the applicant shall provide information regarding the location of windows and the location of any existing Amenity Areas on Abutting properties. Second Storey windows shall be placed and sized such that they reduce overlook into Yards and windows of Abutting properties to the satisfaction of the Development Officer through one or more of the following:

  1. reducing direct views of Rear Yard or Side Yard Amenity Areas, or direct views into a Garden Suite window on an Abutting Site through off-setting window placement, locating windows above eye level, or obscuring windows with translucent treatment;

  2. strategic placement of windows in conjunction with landscaping or the placement of other accessory buildings; and

  3. placing larger windows such as Principal Living Room Windows to face a Lane, a flanking street, or the larger of any Side Yard Abutting another property.

  1. Rooftop Terraces shall not be allowed on Garden Suites.

  2. Platform Structures greater than 1.0 m above Grade shall be fully contained within the rear 6.0 m of the Site, except that they may extend along the full length of a façade facing the Side Lot Line Abutting a flanking public roadway.

  3. Platform Structures greater than 1.0 m above Grade shall provide Privacy Screening to reduce overlook onto Abutting properties.

Charter Bylaw 18662

February 25, 2019

  1.  In order to reduce perceived building mass, Façades shall be articulated to the satisfaction of the Development Officer through two or more of the following:

  1. projection or recession of portions of the façade;

  2. projecting architectural features;

  3. platform structures;

  4. use of two or more exterior finishing materials;

  5. variation in rooflines;

  6. entrance features oriented toward the public roadway, including a Lane;

  7. glazing or windows on the ground floor covering a minimum of 50% of the width of a facade that faces a public roadway, including a Lane;

  8. dormers; or

  9. window trim with a minimum width of 0.075 m.

  1. On Corner Sites the façades facing the Lane and the flanking Side Lot Line shall use consistent building materials and architectural features.

  2. Façades facing a Lane shall have exterior lighting.

  3. Garden Suites shall have a covered entrance feature over the main door.

Charter Bylaw 18967

August 26, 2019

Charter Bylaw 19503

February 9, 2021

Charter Bylaw 19679

June 29, 2021

  1. Only one of a Secondary Suite or Garden Suite may be developed in conjunction with a principal Dwelling, except in the RF1, RF2, RF3, GLG, and GLD Zones where one Secondary Suite and one Garden Suite may both be developed in conjunction with a Single Detached Housing, Multi-unit Housing in the form of Row Housing, or Semi-detached Housing where permitted in the zone.

Charter Bylaw 19490

November 5, 2020

Charter Bylaw 19502

February 9, 2021

  1. A Garden Suite shall not be allowed within the same Site containing Supportive Housing.

  1. Where Garden Suites are Discretionary within the applicable Zone, the Development Officer may exercise discretion in considering a Garden Suite having regard to:

  1. compatibility of the Use with the siting, geodetic elevations, and Height characteristic of surrounding development;

  2. the effect on the privacy of adjacent properties;

  3. the policies and guidelines for Garden Suites contained in a Statutory Plan for the area.

  1. A Garden Suite shall not be subject to separation from the principal Dwelling through a condominium conversion or subdivision.