Bylaw 12809
May 30, 2001
Bylaw 12961
February 4, 2002
Bylaw 13912
March 1, 2005
The Uses listed, as Permitted and Discretionary Uses in Section 160 of this Bylaw, being the (RF5) Row Housing Zone shall be the Permitted and Discretionary Uses for this Zone.
Except as expressly modified in Section 920.6 (3), the development regulations specified in Section 160 of this Bylaw shall regulate development in this Zone.
The following development regulations shall apply to the development of RF5t Zones within the Terwillegar Special Area as identified on Appendix I to this Section:
Charter Bylaw 18967
August 26, 2019
Multi-unit Housing development, when located within the Street Oriented Residential portion of the Terwillegar Towne NASP, as amended, shall only consist of a building containing a row of a maximum of four Dwellings, joined in whole or in part, at the side only, with no Dwelling being placed over another, in whole or in part;
Charter Bylaw 18967
August 26, 2019
notwithstanding Section 920.6 (3)a), Multi-unit Housing development, when located within the Mixed Use Towne Square portion of the Terwillegar Towne NASP, as amended, shall be developed as per Section 160.4(1) of this Bylaw;
Bylaw 15735
June 20, 2011
the minimum Front Setback shall be 3.0 m for Row Housing, Semi-detached Housing and Single Detached Housing development, unless the Development Officer, having regard for the siting and appearance of adjoining residences and other residences within the block face, increases the Front Setback requirement to, improve sunlight exposure, views and privacy or add general interest to the streetscape;
Bylaw 14750
December 12, 2007
the minimum Site Area shall be as follows:
Bylaw 15735
June 20, 2011
Charter Bylaw 18967
August 26, 2019
183 m2 for each Multi-unit Housing Dwelling.
the minimum Site Width shall be 9.0 m. for each Single Detached Dwelling;
Side Setbacks shall be established on the following basis:
the minimum required Side Setback shall be 1.2 m except that a minimum Side Setback for buildings over 7.5 m in Height shall be 2.0 m;
on a corner Site where the building fronts on the Front Yard, the minimum Side Setback Abutting the flanking public roadway other than a Lane shall be 20% of the unit Site Width, to a maximum of 3.0 m; and
on a corner Site where the building fronts on a flanking public roadway, other than a Lane, the minimum Side Setback Abutting the flanking public roadway shall be 3.0 m;
The maximum total Site Coverage shall be 50% with a maximum of 35% for a principal building and 15% for accessory buildings. Where a Garage is attached or designed as an integral part of a Dwelling, the maximum Site coverage for the principal building shall be 45%;
entryways may be placed on the side walls of end Dwellings, provided that:
the entryway is located in the rear 1/3 of the Dwelling; and
the entryway is not located opposite an entryway on a neighbouring Dwelling;
Bylaw 15735
June 20, 2011
unenclosed steps, over 0.6 m but not exceeding 1.0 m in Height to the top of the landing, accessing a side entryway, may encroach into the Side Setback, provided the encroachment does not exceed 0.9 m;
the vehicle doors of a detached Garage shall not face any flanking public roadway;
Bylaw 14750
December 12, 2007
Bylaw 17062
July 9, 2015
Bylaw 18115
July 10, 2017
Effective Date: September 1, 2017
the maximum Height for a detached Garage shall not exceed 5.0 m, except in the case of a Garden Suite, where the maximum Height shall be in accordance with Section 87 of this Bylaw;
Bylaw 17422
November 16, 2015
Effective Date: December 1, 2015
plans of subdivision or condominium plans in this Zone must ensure that each proposed Lot, or Unit in the case of a bareland condominium or condominium conversion, is accessed by a public roadway, a public laneway, condominium common property, or a Unit characterizing condominium common property.